May 2020 | Clinical feasibility and benefits of a tapered, sand-blasted, and acid-etched surfaced tissue-level dental implant

  • Writer: Office Manager
    Office Manager
  • Jun 1, 2020
  • 2 min read
ree
ree

🦷 Clinical Summary:

Title: Clinical feasibility and benefits of a tapered, sand-blasted, and acid-etched surfaced tissue-level dental implantJournal: International Journal of Implant Dentistry (2020)Implant: StellaĀ® Implant (Shinhung) – equivalent to Luna (Evertis SI) except for abutment connection

šŸ“Œ Purpose

To evaluate the long-term clinical outcomes of a tapered, S&E surface-treated tissue-level implant with double-thread design and conical sealing, placed in various clinical conditions.

šŸ” Key Findings

āœ… Implant Survival & Success

  • 105 implants placed in 61 patients (mean age 63.7 years)

  • 98.1% 5-year success rate, with only 2 failures (both in highly compromised posterior maxillary bone)

  • 100% survival for 4.0mm and 4.5mm implants

āœ… Design Benefits

  • 1° tapered body and 2.5° apical taper āžœ excellent primary stability

  • S&E (Sand-blasted & Acid-etched) surface āžœ ~60% bone-to-implant contact

  • Double-thread design (35° helix) āžœ faster insertion and improved stability

  • Helix cutting edge āžœ self-tapping and minimal bone resistance

  • 8° conical seal āžœ strong platform connection with minimal micromovement

āœ… Marginal Bone Loss (MBL)

  • Mean MBL at 5 years:ā–ø Mesial: 0.90 ± 0.61 mmā–ø Distal: 0.74 ± 0.75 mm

  • Well within accepted success thresholds (Albrektsson criteria: <1.5 mm in first year, <0.2 mm/year after)

āœ… Diverse Case Feasibility

  • Success seen in:

    • Posterior mandible and maxilla

    • Sinus graft sites

    • Osteoporotic patients

    • Sites with compromised bone quality



🌟 Clinical Implication for Luna® (Evertis SI) Implant

Even though the StellaĀ® is a tissue-level system, its core structure (tapered body, S&E surface, double-thread, and apex design) is identical to Luna (Evertis SI). This study validates Luna's exceptional performance in the following ways:

šŸ”¹ 1. Strong Primary Stability in All Bone Types

Thanks to the tapered body and helix cutting edge, Luna implants show secure initial fixation—even in soft or grafted bone.

šŸ”¹ 2. Reliable Long-Term Bone Maintenance

The S&E surface of Luna promotes early osseointegration, contributing to minimal marginal bone loss over 5+ years.

šŸ”¹ 3. Surgical Efficiency

Double-threaded body and self-tapping tip allow for rapid, predictable placement, reducing surgical time and trauma.

šŸ”¹ 4. Versatility Across Challenging Cases

This study included elderly, medically compromised, and grafted cases, affirming Luna’s performance across all patient profiles.

šŸ”¹ 5. Minimal Prosthetic Complication Risk

The conical seal ensures tight prosthetic connection and minimizes micro-gap issues, preserving peri-implant health.



šŸŽÆ What This Study Proves About LunaĀ® (Evertis SI)

ā€œSame Engine. Greater Access.ā€This study confirms that the implant core design of LunaĀ® is clinically validated for predictable long-term success, even in compromised cases—without sacrificing surgical ease or biological outcomes.

Ā 
Ā 
Ā 

Comments


bottom of page