May 2020 | Clinical feasibility and benefits of a tapered, sand-blasted, and acid-etched surfaced tissue-level dental implant
- Office Manager
- Jun 1, 2020
- 2 min read


𦷠Clinical Summary:
Title: Clinical feasibility and benefits of a tapered, sand-blasted, and acid-etched surfaced tissue-level dental implantJournal: International Journal of Implant Dentistry (2020)Implant: StellaĀ® Implant (Shinhung) ā equivalent to Luna (Evertis SI) except for abutment connection
š Purpose
To evaluate the long-term clinical outcomes of a tapered, S&E surface-treated tissue-level implant with double-thread design and conical sealing, placed in various clinical conditions.
š Key Findings
ā Implant Survival & Success
105 implants placed in 61 patients (mean age 63.7 years)
98.1% 5-year success rate, with only 2 failures (both in highly compromised posterior maxillary bone)
100% survival for 4.0mm and 4.5mm implants
ā Design Benefits
1° tapered body and 2.5° apical taper ā excellent primary stability
S&E (Sand-blasted & Acid-etched) surface ā ~60% bone-to-implant contact
Double-thread design (35° helix) ā faster insertion and improved stability
Helix cutting edge ā self-tapping and minimal bone resistance
8° conical seal ā strong platform connection with minimal micromovement
ā Marginal Bone Loss (MBL)
Mean MBL at 5 years:⸠Mesial: 0.90 ± 0.61 mm⸠Distal: 0.74 ± 0.75 mm
Well within accepted success thresholds (Albrektsson criteria: <1.5 mm in first year, <0.2 mm/year after)
ā Diverse Case Feasibility
Success seen in:
Posterior mandible and maxilla
Sinus graft sites
Osteoporotic patients
Sites with compromised bone quality
š Clinical Implication for LunaĀ® (Evertis SI) Implant
Even though the StellaĀ® is a tissue-level system, its core structure (tapered body, S&E surface, double-thread, and apex design) is identical to Luna (Evertis SI). This study validates Luna's exceptional performance in the following ways:
š¹ 1. Strong Primary Stability in All Bone Types
Thanks to the tapered body and helix cutting edge, Luna implants show secure initial fixationāeven in soft or grafted bone.
š¹ 2. Reliable Long-Term Bone Maintenance
The S&E surface of Luna promotes early osseointegration, contributing to minimal marginal bone loss over 5+ years.
š¹ 3. Surgical Efficiency
Double-threaded body and self-tapping tip allow for rapid, predictable placement, reducing surgical time and trauma.
š¹ 4. Versatility Across Challenging Cases
This study included elderly, medically compromised, and grafted cases, affirming Lunaās performance across all patient profiles.
š¹ 5. Minimal Prosthetic Complication Risk
The conical seal ensures tight prosthetic connection and minimizes micro-gap issues, preserving peri-implant health.
šÆ What This Study Proves About LunaĀ® (Evertis SI)
āSame Engine. Greater Access.āThis study confirms that the implant core design of LunaĀ® is clinically validated for predictable long-term success, even in compromised casesāwithout sacrificing surgical ease or biological outcomes.